IB-20-2510-1354 2.25 CuFt Iron Breaker-Non Chemical Iron Filter w/Fleck 2510 Control Valve and Air Injector Build In.
The Iron Filter is designed for use whenever iron is problematic in the water supply. When water enters the Iron Filter, it passes through a pocket of compressed air that incorporates oxygen. The water then passes through a filter bed, creating a reaction that separates the iron particles from the water. The filter catches the iron particles, leaving iron-free water for use in all water applications. The Iron Filter refreshes itself every three days in a process that washes the iron out from the filter, down the drain, and refills the compressed air pocket at a scheduled time.
- Regeneration Cycle (59 minutes):
- Backwash (14 minutes): During this cycle, the water carrying the iron runs to the drain. Untreated water is available during regeneration.
- Air Recharge (40 minutes): During this cycle, the unit empties water to drain and is recharged with with air. The sound of air being recharged will be heard. Air bubbles should go down to the drain before proceeding to the next step. Adjust cycle time if necessary.
- Rapid Rinse (5 minutes):During this cycle, water enters the tank, compressing the air into a pocket at the top of the tank.
Iron Breaker Manual Breaker Specification
|